     World's Finest Mechanical Draft Systems and Kitchen Ventilation Products.
 | Enervex Chimney FansModel RS Chimney Fan Selection
 Wood and Gas Fired Fireplaces and Stoves
 |  QUICK SIZING....  STEP 1      
Determine the type of opening, measure and calculate..... 
	
		|  |  |  |  |  |  |  |  |  |  |  |  
		| One-sided |  | Two-sided (See-through) |  | Corner |  | Three-sided |  | Free-standing |  | Free-standing Round |  
		| A x B |  | 1.5 x A x B |  | A x B |  | ( A + B ) x C |  | 1.5 x A x B |  | 1.185 x A2 |  
 
	
		| QUICK SIZING.... STEP 2
 | Determine the type of flue and measure the INSIDE measurement... use the 
		chart below to convert square and rectangular to round. |  CONVERSION 
OF Rectangular / 
Square to Round Flues 
	
		| 
		 | 
		Measure the INSIDE ( side to side ) measurements of the clay liner.
  Ex...  The INSIDE measurement of 6 x 10" 
    	on a clay liner is equivalent to
 10 (dim. 
    A) - 6 (dim. 
    B) = 8 (8" 
    Flue Size)
 
		NOTE:  Clay liners are "called" 
		by their OUTSIDE measurements, the INSIDE measurements may vary 
		depending on the manufacturer and location.EX. A 13x13 clay liner may 
		only have an INSIDE measurement of 10" x 10"
 |  
   
		
			| QUICK SIZING.... STEP 
	3
 | Use of the following fan 
selection tables below to calculate the Exhausto fan required to fully exhaust the 
			fireplace opening and flue system. |    
  
    |  | The "opening in square 
    inches" refers to the fireplace or appliances over-all face opening. Example :  In a small wood burning fireplace, if the hearth opening is 
    18" x 24" with an 8" round ( INSIDE MEASUREMENT ) clay liner in a brick and mortar chimney we 
    would... Multiply the length and width, in this case 18" x 24" = 432 square 
    inches.  Being less than 600, on the wood burning chart above, follow the column to the 8" 
    flue size.  Highlighted in 
	orange, the chart shows an RS 9 to be the proper 
    size chimney fan for this application. |  The
RED background 
indicates that the fan will most likely create some air-flow noise due to a high 
air velocity in the chimney.  The BLUE 
background indicates the fan base will not cover the chimney opening and a 
special adapter must be used. 
  
    |  | Fireplaces (wood-fired) |  
    |  | Fireplace Opening in square inches |  
    | Flue 
    Size | Max. 400 | Max. 600 | Max. 
	900 | Max. 
	1200 | Max. 
	1500 | Max. 
	2000 | Max. 
	2500 | Max. 
	3300 |  
    | 5 | RS 12 | RS 16 | * | * | * | * | * | * |  
    | 6 | RS 9 | RS 12 | RS 16 | * | * | * | * | * |  
    | 7 | RS 9 | RS 9 | RS 14 | RS 16 | * | * | * | * |  
    | 8 | RS 9 | RS 9 | RS 12 | RS 14 | RS 16 | * | * | * |  
    | 9 | RS 9 | RS 9 | RS 12 | RS 14 | RS 16 | RS 16 | * | * |  
    | 10 | RS 9 | RS 9 | RS 12 | RS 12 | RS 14 | RS 16 | * | * |  
    | 12 | RS 9 | RS 9 | RS 12 | RS 12 | RS 14 | RS 14 | RS 16 | * |  
    | 14 | RS 9 | RS 9 | RS 12 | RS 12 | RS 12 | RS 12 | RS 14 | RS 16 |  
    | 16 | RS 9 | RS 9 | RS 12 | RS 12 | RS 12 | RS 12 | RS 14 | RS 16 |  
    | 18 | RS 9 | RS 9 | RS 12 | RS 12 | RS 12 | RS 12 | RS 14 | RS 16 |  
    | 20 | RS 9 | RS 9 | RS 12 | RS 12 | RS 12 | RS 12 | RS 14 | RS 16 |  
    | 22 | RS 9 | RS 9 | RS 12 | RS 12 | RS 12 | RS 12 | RS 14 | RS 16 |  
    | 24 | RS 9 | RS 9 | RS 12 | RS 12 | RS 12 | RS 12 | RS 14 | RS 16 |  If there are more than 2x90° elbows,  
a bigger fan may be necessary. 
 
	
		
		| Short Flue System? The RSHT Chimney Fan is a high temperature exhaust fan that can handle 1000+ 
	degrees at the termination.
 |  |  
		
		| Need help sizing?  Need 
		help for fan selection? 800 685 8263   
		info@volko.com
 | RSHT High Heat Fan Wood / Gas Fireplaces
 |  
		
		| RSHT 009 - 016 |  
   Gas fireplaces will need additional controls... PDS (Proven Draft Switch) Safety control that senses 
a draft.  A pressure sensor that ties into the log set or appliance 
controls and would shut the gas off if the draft became negative. ADC100 -  A pre/post purge control that would extend the 
the fan cycle before and after gas is present for a fireplace or appliance. Note: The
RED background 
indicates that the fan will most likely create some air-flow noise due to a high 
air velocity in the chimney.  The BLUE 
background indicates the fan base will not cover the chimney opening and a 
special adapter must be used. 
  
    |  | Fireplaces (gas-fired) |  
    |  | Fireplace Opening in square inches |  
    | Flue 
    Size | Max. 400 | Max. 600 | Max. 1000 | Max. 2000 | Max. 2500 | Max. 3000 | Max. 3500 | Max. 5000 |  
    | 5 | RS 9 | RS 12 | * | * | * | * | * | * |  
    | 6 | RS 9 | RS 9 | RS 12 | * | * | * | * | * |  
    | 7 | RS 9 | RS 9 | RS 12 | RS 14 | RS 14 | * | * | * |  
    | 8 | RS 9 | RS 9 | RS 9 | RS 12 | RS 16 | * | * | * |  
    | 9 | RS 9 | RS 9 | RS 9 | RS 12 | RS 12 | * | * | * |  
    | 10 | RS 9 | RS 9 | RS 9 | RS 12 | RS 14 | RS 16 | RS 16 | * |  
    | 12 | RS 9 | RS 9 | RS 9 | RS 12 | RS 14 | RS 14 | RS 16 | * |  
    | 14 | RS 9 | RS 9 | RS 9 | RS 12 | RS 14 | RS 14 | RS 14 | * |  
    | 16 | RS 9 | RS 9 | RS 9 | RS 12 | RS 14 | RS 14 | RS 14 | * |  
    | 18 | RS 9 | RS 9 | RS 9 | RS 12 | RS 14 | RS 14 | RS 14 | RS 16 |  
    | 20 | RS 9 | RS 9 | RS 9 | RS 12 | RS 14 | RS 14 | RS 14 | RS 16 |  
    | 22 | RS 9 | RS 9 | RS 9 | RS 12 | RS 14 | RS 14 | RS 14 | RS 16 |  
    | 24 | RS 9 | RS 9 | RS 9 | RS 12 | RS 14 | RS 14 | RS 14 | RS 16 |  If there are more than 2x90° elbows,  
a bigger fan may be necessary. 
Please call 800 685 8263 
or email 
us 
(info@volko.com)  
 
	
		| Wood stoves, coal stoves 
		and fireplace inserts  
  
    |  | Stoves | Fireplace Inserts |  
    |  | Door Opening in square inches     A x B |  
    | Flue 
    Size | Max. 300 | OVER  300 |  
    | 6 | RS 9 | RS 12 |  
    | 7 | RS 9 | RS 12 |  
    | 8 | RS 9 | RS 12 |  
    | 9 | RS 9 | RS 12 |  
    | 10 | RS 9 | RS 12 |  |  
			
				| If there are more than 2x90° elbows,  
a bigger fan may be necessary. |  |  
 
   Fan Specifications                                                         
800 685 8263 or email 
us 
(info@volko.com) 
			
				| 
				 | 
				 
				 | 
			
				| Fan 
				Model | Part 
				Number |  
				| RS 009 | 101.0299.1200 |  
				| RS 012 | 101.0499.1200 |  
				| RS 014 | 101.0699.1200 |  
				| RS 016 | 101.0899.1200 |  
 Capacitor
 Wiring Diagram
 
 1 Junction Box 
    Capacitor2 Conduit/cord
 3 Motor
 4 Motor Housing
 5 Cooling Plates
 6 Bird Screen
 7 
    Base Plate
 8 
    Locking Nut
 9 
    Inlet
 10 
    Axial Vane
 11 
    Hinges
 12
 ( inside J-box )
 |  RS Chimney Adaptors 
will be necessary for any metal pipe installation. 
	
		|  | SCA - Steel Chimney Adapter 
 The ENERVEX Steel Chimney Adapter is used when installing the RS chimney 
		fan on the top of a single, double or triple wall steel chimney. The 
		adapter is designed to slide into the steel chimney for a tight fit. The 
		outer diameter of the collar is 1/8” smaller than the inner diameter of 
		the steel chimney, and has a 5” deep collar.
  SCA Adaptor           
 Product Info PDF |  
		|  | ASCA - Air-cooled Steel Chimney Adapter 
 The ENERVEX Air-Cooled Steel Chimney Adapters are used specifically when 
		installing a chimney fan on the top of a double-walled, air-cooled 
		chimney.
 
 The adapter is designed to slide into the chimney for a tight fit. The 
		outer diameter of the collar is 1/8" smaller than the inner diameter of 
		the chimney. The 5" collar eliminates the need to secure the adapter 
		externally.
  ASCA Adaptor        
 Product Info PDF |  
 
 Enervex?... but 
my new fan says Exodraft.Exhausto is now Exodraft, distributed as Enervex.  
Read More...
 Enervex Fans... draft solutions for kitchen and 
pizza oven exhaust.
 Please call 800 685 8263 
or email 
us 
(info@volko.com) for 
prices 
 
 
	
		|  |  |  |  |  |  |  
		| Fan Controls Draft Switches
 | EcoDamper System
 | Downloadable PDF's Product Literature
 | Motors - Impellers Capacitors
 | Maintenance from Oven Deck to Fan
 | Enervex Fan Source |  
		| CONTROLS | MFD - FDDS | LIBRARY | PARTS | FAN FAIL | HOME |  
   |